RCF are electronic fan-coil thermostats for room temperature control, with PI controller. The controllers have automatic change-over between heating and cooling and can be used for 2- or 4-pipe systems. They have a function for control of a 3-speed fan (for fan-coil), a butli-in temperature sensor, back lit display, and an input for a window contact or an occupancy detector.
The thermostat is suitable in buildings where you want optimal comfort and reduced energy consumption, for example offices, schools, shopping centres, airports, hotels, hospitals etc.
Protection class | IP20 |
Manufacturer | Regin |
Setpoint | 5...35°C |
Mounting | Room |
Supply voltage | 230V AC, 50...60Hz |
Digital input | One closing potential-free contact |
Analog inputs | One PT1000 |
Name | Communication | Output | Fan control | ||
---|---|---|---|---|---|
RCF-230D | - | on/off | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, DO - 5 | |||||
RCF-230CD | RS485: Modbus, EXOline, BACnet | on/off | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, DO - 5 | |||||
RCFM-230D | - | on/off | 3-step | Buy in the store | |
Installations 2-pipe manual change-over function inputs/outputs: AI - 1, DI - 1, UI - , DO - 5 | |||||
RCF-230TD | - | 3 position or thermal actuator | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, DO - 5 | |||||
RCF-230CTD | Modbus, BACnet, EXOline | 3 position or thermal actuator | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, DO - 5 | |||||
RCF-230CTD-EC | Modnus, BACnet, EXOline | on/off or thermal actuator | EC | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, AO - 1, DO - 2 | |||||
RCF-230AD | - | 0…10 V | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, AO - 2, DO - 3 | |||||
RCF-230CAD | Modbus, BACnet, EXOline | 0…10 V | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic change-over function inputs/outputs: AI - 1, DI - 1, UI - 1, AO - 1, DO - 3 | |||||
RCFD-230C | EXOline,Modbus | on/off | 3-step | Buy in the store | |
Installations 2- lub 4-pipe automatic or manual change-over function inputs/outputs: DI - 1, DO - 5, AI - 1 |