EXNT Pressure Transducer

EXNT Pressure Transducer

Industrial Pressure Transducer 8292 ATEX

Pressure Transducer EXNT

Trafag EXNT pressure transmitters are developed based on the already proven, proprietary thin film on steel technology.

It is characterized by high quality, which is why it is used wherever it is installed, where utility devices are installed. Court for a wide range of services.

Certificates

EXNT pressure transmitters have the following certificates: ATEX, IECEx, UKEX. They are made in a safe version that is suitable for use in Ex zones 0, 1, 2 (gas), 20, 21, 22 (dust) and in mining and quarrying.

Proposed applications of the EXNT pressure transmitter:

  • shipbuilding
  • mining
  • other

Trafag pressure transmitters can be made according to specific needs or with specific parameters.
One option is a hydrogen-compatible sensor.
Detailed information can be found in the datasheets. If you have additional questions, please contact us.

Standard executions

Name Pressure Range [bar] Max Overload [bar]
Więcej EXNT0.4A 0…0.4 1.2
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT0.6A 0…0.6 1.5
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT1.0A 0…1 2
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT2.5A 0…2.5 5
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT4.0A 0…4 8
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT6.0A 0…6 12 Buy in the store
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Zasilanie [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT10.0A 0…10 20 Buy in the store
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" męski Output: 4…20 mA
Więcej EXNT16.0A 0…16 32 Buy in the store
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" męski Output: 4…20 mA
Więcej EXNT25.0A 0…25 50
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT40.0A 0…40 80 Buy in the store
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT100.0A 0…100 200
Accuracy: ±0.5% FS Temperatura Medium: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA
Więcej EXNT250.0A 0…250 500
Accuracy: ±0.5% FS Medium Temperature: –40°C...+120°C Power [V DC]: 10...30 Connection: G1/4" male Output: 4…20 mA

Documents to download

EXNT_product data sheet

EXNT_flyer